4.SERVO FUNCTION DETAILS B-65270EN/05
- 276 -
NOTE
1 With position detection circuit H (A860-0333-T201
or A860-0333-T202), the interpolation
magnification can be changed using setting pin
SW3. The pin is factory-set to B to set the
interpolation magnification to 2048. (When the pin
is set to A, the interpolation magnification is set to
512.)
When an input frequency of 750 kHz is to be used,
HP2048 must be set to 1, and setting pin SW3
must also be set to A. Here, calculate the
parameter by using the following:
Resolution [µm] = encoder signal pitch [µm]/128
For details, refer to the specifications of position
detection circuit H.
2 When the position detection circuit C
(A860-0333-T301 or -T302) is used, no function is
available which can change an interpolation
magnification according to a set-up pin.
(Cautions)
• Setting this parameter(No.2274(FS30i,16i) or No.2687(FS15i))
to "enable" lets you make the basic parameter settings as
explained in Procedure (2).
• Changing this parameter results in a power-off alarm being
raised.
• When this parameter is specified, the detection unit is (signal
pitch/512 [µm]) if FFG = 1/1.
If a minimum detection unit (signal pitch/2048 [µm]) is
necessary, specify:
FFG = 4/1
• If nano-interpolation is applied, a resolution as high as (signal
pitch/2048 [µm]) is applied as decimal-part feedback.
Parameter setting procedure (2)
Procedure (2) makes parameter settings that depend on the resolution
of the linear encoder (hereafter simply called "the resolution"). Set the
parameters according to Table 4.14.1 (d), (e).
When using an incremental type linear encoder, calculate as follows:
Resolution [µm] = encoder signal pitch [µm] / 512
The pole-to-pole span used in calculation varies, depending on the
motor model.
Small linear motors: 30 mm (L300Ais, L600Ais, L900Ais)
Medium-size and large linear motors: 60 mm (models other than
the above)
(See Table 4.14.1(c).)