B-65270EN/05 4.SERVO FUNCTION DETAILS
- 243 -
<2> Activation delay
1976 (FS15i)
Brake control timer
2083 (FS30i, 16i)
[Increment system] msec
[Valid data range] 0 to 16000
(Example)
To specify an activation delay of 200 ms, set the brake control
timer usually with 200 (appropriately). Do not set it with 500 or
greater. Also set the timer connected to the emergency stop
contact with the same value as set in the parameter.
<3> Setting the emergency stop timer built into the α
i amplifier
#7 #6 #5 #4 #3 #2 #1 #0
1750 (FS15i)
ESPTM1 ESPTM0
2210 (FS30i, 16i)
ESPTM0 (#5) Set a period of time from the input of the emergency stop signal into
ESPTM1 (#6) the PSM until emergency stop operation is actually performed in the
servo amplifier (SVM).
ESPTM1 ESPTM0 Delay time
0 0 50 ms (default)
0 1 100ms
1 1 200ms
1 1 400ms
When using brake control, set a time longer than the setting of the
brake control timer (No. 1976 for Series 15i or No. 2083 for Series 16i
and so on).
NOTE
For those axes that are connected to a two-axis
amplifier or three-axis amplifier, the parameters
above need to be set in the same way.
(4) Detailed operation
Suppose that there is a machine having horizontal and vertical axes
of motion. When a servo alarm
(*)
occurs on the horizontal axis but no
error occurs on the vertical axis, the MCCs of the amplifiers for all
axes are turned off. When the emergency stop button is pressed, the
MCCs of the amplifiers for all axes are turned off.
Standard machines have a mechanical brake that prevents the tool
from dropping vertically in such cases. The mechanical brake may
actually function according to the timing shown in Fig. 4.10 (c). If this
occurs, the tool will drop vertically, causing the tool or workpiece to
be damaged.
This function changes the timing to force MCC off, using a software
timer, thus preventing the tool from dropping. Fig. 4.10 (d) shows the
timing diagram.