B-65270EN/05 5.DETAILS OF PARAMETERS
- 389 -
☆: Parameters set up automatically at initialization
★: Parameters that can be kept at the automatically set values
Parameter number
Series 15i
Series 30i, 16i,
and so on
Details
1769 2146 Two-stage backlash acceleration end timer → 4.6.7
1771 2148
Deceleration decision level (HRV control)
Usually to be kept at 0.
Usually adjustment is
not needed.
1774 2151 For internal data output: Usually, be sure to set 0.
1775 2152 For internal data output: Usually, be sure to set 0.
1776 2153 For internal data output: Usually, be sure to set 0.
1777 2154
Static friction compensation function : decision level for
movement restart after stop.
→ 4.6.8
1779 2156 Torque command filter (at rapid traverse) → 4.3, 4.5.1
1784 2161 OVC magnification at a stop (OVCSTP)
★ Motor-specific
1785 2162 Soft thermal coefficient 2 (POVC21)
★ Motor-specific
1786 2163 Soft thermal coefficient 2 (POVC22)
★ Motor-specific
1787 2164 Soft thermal coefficient 2 (POVCLMT2)
★ Motor-specific
1788 2165 Maximum amplifier current
★ Motor-specific
1790 2167
2-stage backlash acceleration function : stage 2 acceleration
amount offset
→ 4.6.7
2620 2177 Resonance elimination filter 1: attenuation bandwidth → 4.5.2
2622 2179 Reference counter size (denominator) → 2.1.3
2623 2180
Linear motor thrust ripple correction : phase delay
compensation.
→ 4.14.2
2628 2185 Position pulses conversion coefficient
→ 2.1, 2.1.8, 4.14.1,
Initial setting
2731 2318 Disturbance elimination filter : gain → 4.5.3
2732 2319 Disturbance elimination filter : inertia ratio → 4.5.3
2733 2320 Disturbance elimination filter : inverse function gain → 4.5.3
2734 2321 Disturbance elimination filter : time constant → 4.5.3
2735 2322 Disturbance elimination filter : acceleration feedback limit → 4.5.3
2736 2323 Variable current PI rate → 4.5.5
2737 2324
Variable proportional gain function in the stop state : arbitrary
magnification at a stop (for cutting only)
→ 4.4.3
2738 2325
Tandem disturbance elimination control function/integral gain
(main axis)
Tandem disturbance elimination control function/phase
coefficient (sub-axis)
→ 4.16
2739 2326 Disturbance input : gain → Appendix H
2740 2327 Disturbance input : start frequency → Appendix H
2741 2328 Disturbance input : end frequency → Appendix H
2742 2329 Number of disturbance input measurement points → Appendix H
2746 2333
Tandem disturbance elimination control function /incomplete
integral time constant (main axis)
→ 4.16
2747 2334
Current loop gain magnification (enabled only during
high-speed HRV current control)
→ 4.2
2748 2335
Velocity loop gain magnification (enabled only during
high-speed HRV current control)
→ 4.2
2751 2338
Backlash acceleration function : acceleration amount limit value
2-stage backlash acceleration function : stage-2 acceleration
amount limit value
→4.6.6
→4.6.7