B-65270EN/05 5.DETAILS OF PARAMETERS
- 369 -
PRMC (#3) Do not change. (
)
PGEX (#4) The position gain range is:
0: Not expanded .
1: Expanded by 8 times.
[Reference item] Subsection 2.1.5
#7 #6 #5 #4 #3 #2 #1 #0
1806 (FS15i)
0 AMR6 AMR5 AMR4 AMR3 AMR2 AMR1 AMR0
2001 (FS30i, 16i)
AMR0 to ARM7 (#0 to #7) Specify the AMR value according to the Pulsecoder model for the
motor.
AMR
6 543210
0 001000
16-pole servo motors
α2000/2000HVis, α3000/2000HVis
0 000000
Other than 16-pole servo motor
(8-pole servo motors)
[Related parameters] 2608#5 (15i), 2220#5 (16i etc.)
#7 #6 #5 #4 #3 #2 #1 #0
1807 (FS15i)
PFSE
2002 (FS30i, 16i)
PFSE (#3) A separate detector is:
0: Not used.
1: Used .
Specify this parameter only in the Series 15i.
In the Series 16i, 18i, 21i, 0i, and Power Mate i, setting bit 1 of
parameter No. 1815 (OPT) to 1 automatically specifies this parameter.
[Reference item] Subsection 2.1.3
#7 #6 #5 #4 #3 #2 #1 #0
1808 (FS15i)
VOFS OVSC BLEN NPSP PIEN OBEN TGAL
2003 (FS30i, 16i)
TGAL (#1) The software disconnection alarm detection level is:
0: Standard setting.
1: Lower sensitivity specified elsewhere.
[Related parameters] 1892 (15i), 2064 (16i etc.)
OBEN (#2) The velocity control observer function is:
0: Not used.
1: Used .
[Reference item] Subsection 4.5.4
[Related parameters] 1859 (15i), 2047 (16i etc.), 1862 (15i), 2050 (16i etc.), 1863 (15i),
2051 (16i etc.)
PIEN (#3) The velocity control method to be used is:
0: I-P
1: PI