B-65270EN/05 4.SERVO FUNCTION DETAILS
- 277 -
#7 #6 #5 #4 #3 #2 #1 #0
1804 (FS15i)
PLC0
2000 (FS30i, 16i)
PLC0(#0) The number of velocity pulses and the number of position pulses are:
0: Used without being modified.
1: Used after being multiplied by 10
If the number of velocity pulses is lager than 32767, set the parameter
to 1.
If the number of position pulses exceeds 32767, use the following
position pulse conversion coefficient.
1876 (FS15i)
Number of velocity pulses
2023 (FS30i, 16i)
(Parameter calculation expression)
Number of velocity pulses = 3125 / 16 / (resolution [µm])
If the calculation result is greater than 32767, set up PLC0 = 1, and set
the parameter (PULCO) with a value of 1/10.
1891 (FS15i)
Number of position pulses
2024 (FS30i, 16i)
(Parameter calculation expression)
Number of position pulses = 625 / (resolution [µm])
If the calculation result is greater than 32767, determine the parameter
setting (PPLS), using the following position pulse conversion
coefficient (PSMPYL).
2628 (FS15i)
Position pulses conversion coefficient
2185 (FS30i, 16i)
This parameter is used if the calculated number of position pulses is
greater than 32767.
(It can be specified in the Series 90B0, 90B1, 90B6, 90B5, 90D0, or
90E0.)
(Parameter calculation expression)
PLC0 = 0 → The parameter is set so that the following equation
holds: (the number of position pulses) × (position pulses conversion
coefficient) = 625/resolution [µm].
PLC0 = 1 → The parameter is set so that the following equation
holds: 10 × (the number of position pulses) × (position pulses
conversion coefficient) = 625/resolution [µm].
(→ See Supplementary 3 of Subsection 2.1.8.)
#7 #6 #5 #4 #3 #2 #1 #0
1707 (FS15i)
APTG
2013 (FS30i, 16i)
APTG(#7) When using an absolute type linear encoder, set this bit to:
1: Ignores an α Pulsecoder soft disconnection.