4.SERVO FUNCTION DETAILS B-65270EN/05
- 290 -
Parameter setting procedure (5)
Procedure (5) can be used to set parameters according to the cooling
method used for linear motors.
Change the following parameters as listed in Table 4.14.1 (f). For
self-cooling linear motors, the parameters need not be set here,
because they are set up at initialization in procedure (1).
1877 (FS15i)
OVC alarm parameter (POVC1)
2062 (FS30i, 16i)
1878 (FS15i)
OVC alarm parameter (POVC2)
2063 (FS30i, 16i)
1893 (FS15i)
OVC alarm parameter (POVCLMT)
2065 (FS30i, 16i)
1979 (FS15i)
Current rating parameter (RTCURR)
2086 (FS30i, 16i)
1784 (FS15i)
OVC magnification in stop state (OVCSTP)
2161 (FS30i, 16i)
Table4.14.1 (f) Setting OVC and current rating parameters by cooling method
[200-V driving]
Model
Cooling
method
Rated
(N)
POVC1 POVC2 POVCLMT RTCURR OVCSTP
No cooling 50 32704 802 793 655 0
LiS300A1/4
Water cooling 100 32512 3199 3172 1310 0
No cooling 100 32704 802 793 655 0
LiS600A1/4
Water cooling 200 32512 3199 3172 1310 0
No cooling 150 32705 785 1784 983 0
LiS900A1/4
Water cooling 300 32518 3129 7136 1966 0
No cooling 300 32698 873 2590 1184 0
LiS1500B1/4
Water cooling 600 32490 3481 10358 2368 0
No cooling 600 32711 719 2131 1074 0
LiS3000B2/2
Water cooling 1200 32539 2867 8523 2148 0
No cooling 600 32698 873 2590 1184 0
LiS3000B2/4
Water cooling 1200 32490 3481 10358 2368 0
No cooling 900 32707 758 1199 805 0
LiS4500B2/2
Water cooling 1800 32526 3023 4794 1611 0
No cooling 1200 32711 719 2131 1074 0
LiS6000B2/2
Water cooling 2400 32539 2867 8523 2148 0
No cooling 1200 32698 873 2590 1184 0
LiS6000B2/4
Water cooling 2400 32528 3003 8932 2368 140
No cooling 1500 32707 765 832 671 0
LiS7500B2/2
Water cooling 3000 32524 3053 3329 1342 0