2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS B-65270EN/05
- 52 -
Supplementary 2: Control cycle setting
There are four different types of control cycle setting (HRV1, HRV2,
HRV3, and HRV4). Their settings are explained below.
For Series 15
i
HRV1: No1809=0X000110
HRV2: No1809=0X000011, No1707#0=0
HRV3: No1809=0X000011, No1707#0=1
For Series 16
i and so on
HRV1: No2004=0X000110
HRV2: No2004=0X000011, No2013#0=0
HRV3: No2004=0X000011, No2013#0=1
For Series 30
i
HRV2: No2004=0X000011, No2013#0=0, No2014#0=0
HRV3: No2004=0X000011, No2013#0=1, No2014#0=0
HRV4: No2004=0X000011, No2013#0=0, No2014#0=1
When an invalid value is set in control cycle related parameters, the
following alarm messages are indicated on the CNC:
Alarm detail No. Alarm number Message
10092
10093
456 Invalid current control cycle setting
10103 457 Invalid High-speed HRV setting
10113 458 Invalid current control cycle setting
10123 459 High-speed HRV setting not allowed
10133 468
High-speed HRV setting not allowed
(amplifier)
Supplementary 3: Setting the number of position pulses
If the resolution of the separate detector is high and the number of
position feedback pulses becomes greater than 32767, take the
following measure.
(a) For other than servo software Series 9096
Use "position feedback pulse conversion coefficient" to make settings.
Number of position feedback pulses = A × B
Select B so that A is within 32767.
A: Number of position feedback pulses set in the parameter (less
than or equal to 32767)
B: Conversion coefficient for the number of position feedback
pulses
1891 (FS15i)
Number of position feedback pulses
2024 (FS30i, 16i)
2628 (FS15i)
Conversion coefficient for the number of position feedback pulses
2185 (FS30i, 16i)