I.SERVO CHECK BOARD OPERATING PROCEDURE APPENDIX B-65270EN/05
- 522 -
(5) VCMD signal
When the feed-forward function is not used, the VCMD signal
conveys a velocity command.
With this signal, it is possible to measure very slight vibration in the
motor and its motion irregularity.
When the feed-forward function is used, the VCMD signal represents
a positional deviation rather than a velocity command. So the signal
can be used to measure vibration in the motor and irregularity in the
feed distance of the tool driven by the motor.
The signal conversion type for the VCMD signal can be switched
using parameters.
This switching is used, if the signal waveform is hard to observe
because of the VCMD signal being reciprocating within ±5 V.
#7 #6 #5 #4 #3 #2 #1 #0
No. 1956 (FS15i)
VCM2 VCM1
No. 2012 (FS16i)
Parameters for rotational motor
VCM2 VCM1 Specified rotation speed/5 V
0 0 0.9155 min
-1
0 1 14 min
-1
1 0 234 min
-1
1 1 3750 min
-1
Parameters for linear motor (Incremental type : P=signal pitch[µm])
(Absolute type : P= resolution [
µm] × 512)
VCM2 VCM1 Specified velocity/5 V
0 0 0.00375 × P m/min
0 1 0.006 × P m/min
1 0 0.96 × P m/min
1 1 15.36 × P m/min
Using an oscilloscope to see the movement of the entire signal in DC
mode, then its magnified image in AC mode enables you to check
very slight vibration in the motor and its motion irregularity.
DC mode
AC mode
Enlarged
Fig. I (d) Waveform of the VCMD signal