2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS B-65270EN/05
- 28 -
#7 #6 #5 #4 #3 #2 #1 #0
2687 (FS15i)
HP2048
2274 (FS30i, 16i)
HP2048(#0) The 2048-magnification interpolation circuit (high-resolution serial
output circuit H or C) is:
1: To be used
0: Not to be used
NOTE
This function bit can be used with the following
series and editions:
(Series 30i, 31i, 32i)
Series 90D0/A(01) and subsequent editions
Series 90E0/A(01) and subsequent editions
(Series 15i-B, 16i-B, 18i-B, 21i-B, 0i-B, 0i Mate-B,
Power Mate i)
Series 90B0/Q(17) and subsequent editions
Series 90B1/A(01) and subsequent editions
Series 90B6/A(01) and subsequent editions
(Series 0i-C, 0i Mate-C, 20i-B)
Series 90B5/A(01) and subsequent editions
If this bit is specified, the minimum resolution
setting of the detector is assumed to be:
Encoder signal pitch/512 [µm]
If the minimum resolution (signal pitch/2048 [µm])
is necessary as the detection unit, specify:
Flexible feed gear = 4/1
[Minimum resolution of the detector]
In the following calculation of a flexible feed gear and the number of
position pulses, the minimum detector resolution to be used is:
(Linear encoder signal pitch/512 [µm])
(Specifying the above function bit appropriately makes it unnecessary
to take the difference in the interpolation magnification among the
high-resolution serial output circuits into account. So always use 512
for calculations.)
[Flexible feed gear]
Parameters Nos. 1977 and 1978 (Series 15i) or Nos. 2084 and 2085
(Series 30
i, 16i, and so on)
Flexible feed gear (N/M)
= minimum resolution of the detector [µm] /
detection unit of controller [µm]