B-65270EN/05 5.DETAILS OF PARAMETERS
- 379 -
PIAL (#2) When rapid traverse is selected by the cutting/rapid velocity loop gain
switching function, the 1/2 PI control function is:
0: Automatically disabled.
1: Always enabled.
[Reference item] Subsection 4.5.5
OVS1 (#3) 1: Overshoot compensation is valid only once after the termination
of a move command.
[Reference item] Section 4.7
DUAL (#4) Zero width is determined:
0: Only by setting = 0.
1: By setting.
[Reference item] Subsection 4.5.7
[Related parameters] 1974 (15i), 2081 (16i etc.)
#7 #6 #5 #4 #3 #2 #1 #0
1743 (FS15i)
TCMD4X FRCAX2 CRPI
2203 (FS30i, 16i)
CRPI (#2) The current loop 1/2 PI control function is:
0: Not used.
1: Used .
[Reference item] Subsection 4.5.5
FRCAX2 (#4) Torque control type 2 is:
0: Not exercised .
1: Exercised.
[Reference item] Section 4.15
TCMD4X (#5) The check board output voltage of the TCMD signal is:
0: As usual (default).
1: Multiplied by 4.
[Reference item] Appendix I
#7 #6 #5 #4 #3 #2 #1 #0
1744 (FS15i)
DBS2
PGTWN2
HSTP10
2204 (FS30i, 16i)
HSTP10 (#1) The valid speed increment system for the high-speed positioning
function is:
0: 0.01mm
-1
(rotary motor), 0.01mm/min (linear motor).
1: 0.1mm
-1
(rotary motor), 0.1mm/min (linear motor).
[Reference item] Subsections 4.8.1 and 4.8.2
PGTWN2 (#5) Position gain switching type 2 is:
0: Not used.
1: Used .
[Reference item] Subsection 4.8.1
[Related parameters] 1713 (15i), 2028 (16i etc.)