B-65270EN/05 3. αiS/αiF/βiS SERIES PARAMETER ADJUSTMENT
- 73 -
(4) Servo HRV control setting
Set the type of servo HRV control. The setting of servo HRV2 is
always required. So, load the standard parameters for servo HRV2 by
following the description given below. Then, set HRV3 or HRV4 as
necessary.
(For Series 30i)
In standard setting, servo HRV2 control is set. However, to make
high-speed and high-precision adjustments, servo HRV3 is
recommended. If sufficient precision cannot be obtained with
servo HRV3, consider using servo HRV4. (See Subsec. 4.2.2.)
(For other than Series 30i)
In standard setting, servo HRV2 control is set. However, if
sufficient precision cannot be obtained with servo HRV2,
consider using servo HRV3. (See Subsec. 4.2.1.)
(a) Servo HRV2 control
By setting a motor ID number for servo HRV2 control, load the
standard parameters.
NOTE
If there is no motor ID number for servo HRV2
control, load the standard parameters for servo
HRV1, then calculate parameter values as follows:
No. 2004 = 0X000011 (Keep X unchanged.)
No. 2040 = Standard parameter for HRV1 × 0.8
No. 2041 = Standard parameter for HRV1 × 1.6
(b) Servo HRV3 control
After setting servo HRV2 control, set the following parameters:
[HRV3 parameters]
Parameter No.
FS15i FS30i, 16i, and so on
Recommended
value
Description
1707#0 2013#0 1 Enables HRV3 current control.
1742#1 2202#1 1
Enables the cutting/rapid velocity loop gain
switching function.
- 2283#0 1
Enables high-speed HRV current control in
cutting feed
(Note 1)
.
2747 2334 150 Current gain magnification in HRV3 mode
2748 2335 200 Velocity gain magnification in HRV3 mode
NOTE
1 With Series 90B0, 90B1, 90B6, and 90B5, the torque command
during HRV3 control is limited to 70% of the maximum value. (This
limitation does not apply to Series 90D0 and 90E0.)
2 With Series 90E0, use of servo HRV3 control decreases the
maximum number of axes per servo card.
3 To use HRV3 control, G codes must be set. (HRV3 control is
enabled between G5.4Q1 and G5.4Q0.)
4 Bit 0 of parameter No. 2283 is valid for the Series 30i. When bit 0 of
parameter No. 2283 is set to 1, G codes are not required.