4.SERVO FUNCTION DETAILS B-65270EN/05
- 124 -
4.2.3 High-speed HRV Current Control
(1) Starting the high-speed HRV current control mode
The high-speed HRV current control mode is turned on and off by
using a G code (G5.4). The high-speed HRV current control mode is
set for cutting commands specified between G5.4Q1 and G5.4Q0.
(2) Checking the high-speed HRV current control mode
Diagnosis No. 700 is used for checking the status
of the high-speed HRV current control mode in
servo HRV3 control and servo HRV4 control.
After setting servo HRV3 or HRV4 control and
turning the power off then back on, check that bit
1 (HOK) of diagnosis No. 700 is set. When servo
HRV3 or HRV4 control can be used, HOK is set
to 1.
When HOK is set to 1, specifying G5.4Q1 sets
bit 0 (HON) of diagnosis DGN700 to 1 during
the cutting feed command. If NOG54 is set to 1,
bit 0 is set to 1 during the cutting feed command
even if G5.4Q1 is not specified.
When HON is set to 1, a high-speed current
control cycle is set, and the current gain
magnification for high-speed HRV current
control is applied.
High-speed HRV
current control mode