A.ANALOG SERVO INTERFACE SETTING PROCEDURE APPENDIX B-65270EN/05
- 420 -
(b) Directly enter all parameters listed in the following table.
Before doing this, understand the meaning of each parameter
sufficiently. For detailed descriptions about parameter setting,
refer to the respective CNC Connection Manuals and Parameter
Manuals. Analog and digital servo axes can be used together as
shown in the reference examples below.
Parameter number
FS15i FS16i, PMi FS30i
Meaning
1023 1023 1023 Servo axis number for each axis
1093#6,7 1905#6,7 1905#6,7,1,2 Selection of interface unit used
1080 to 1089
1120 to 1129
1910 to 1919
1970 to 1979
14340 to 14357
14358 to 14375
Conversion table value for slave number
1094 1936 1936 Connector number for interface unit 1
1095 1937 1937 Connector number for interface unit 2
- - 1938 Connector number for interface unit 3
- - 1939 Connector number for interface unit 4
- - 14376 to 14383
Conversion table value for connector number of
interface unit 1
- - 14384 to 14391
Conversion table value for connector number of
interface unit 2
- - 14392 to 14400
Conversion table value for connector number of
interface unit 3
- - 14401 to 14407
Conversion table value for connector number of
interface unit 4
1100 to 1109
1130 to 1139
- -
Conversion table value for number of slave
connected to 1st axis card on additional-axis
board
1110 to 1119
1140 to 1149
- -
Conversion table value for number of slave
connected to 2nd axis card on additional-axis
board
- - 14408 to 14425
Conversion table value for slave number on
additional-axis board
- - 14444 to 14451
Conversion table value for connector number of
interface unit 1 on additional-axis board
- - 14452 to 14459
Conversion table value for connector number of
interface unit 2 on additional-axis board