B-65270EN/05 4.SERVO FUNCTION DETAILS
- 273 -
Parameter setting procedure (1)
Procedure (1) can be used to initialize the parameters (such as current
gain) necessary to drive a linear motor. After initialization, parameters
depending on the linear encoder resolution (or the value obtained by
dividing the signal pitch of the linear encoder by the interpolation
magnification of the position detection circuit) must be set. Set these
parameters by following parameter setting procedure (2).
Parameters related to initialization
#7 #6 #5 #4 #3 #2 #1 #0
1804 (FS15i)
DGPR PLC0
2000 (FS30i, 16i)
DGPR(#1) Set 0. (After initialization, this bit is set to 1 automatically.)
For PLCO (#0), see Table 4.14.1(d) and Table 4.14.1(e).
1806 (FS15i)
AMR
2001 (FS30i, 16i)
Specify 00000000.
1879 (FS15i)
Movement direction
2022 (FS30i, 16i)
(a) When the coil slider is movable:
+111: When the positive direction is specified, the slider moves
in the positive direction.
-111: When the positive direction is specified, the slider moves
in the reverse direction.
Positive
direction
Slider movable
Magnet plate fixed
Power line
(b) When the magnet plate is movable:
+111: When the positive direction is specified, the magnet plate
moves in the positive direction.
-111: When the positive direction is specified, the magnet plate
moves in the reverse direction.
Positive
direction
Slider fixed
Power line
Magnet plate movable