5.DETAILS OF PARAMETERS B-65270EN/05
- 374 -
#7 #6 #5 #4 #3 #2 #1 #0
1955 (FS15i)
TMPABS RCCL FFAL EGB
2011 (FS30i, 16i)
EGB (#0) The EGB function is:
0: Not used.
1: Used .
FFAL (#1) Feed-forward control always is:
1: Enabled in all modes.
[Reference item] Subsection 4.6.1
[Related parameters] 1961 (15i), 2068 (16i etc.)
RCCL (#5) The actual current torque limit variable function is:
0: Not used.
1: Used.
[Related parameters] 1995 (15i), 2102 (16i etc.)
(
Do not change)
TMPABS (#7) Temporary absolute coordination setting function is:
0: Not used.
1: Used.
#7 #6 #5 #4 #3 #2 #1 #0
1956 (FS15i)
STNG VCM2 VCM1 MSFE
2012 (FS30i, 16i)
MSFE (#1) The machine speed feedback function is:
0: Not used.
1: Used .
[Reference item] Subsection 4.5.8
[Related parameters] 1981 (15i), 2088 (16i etc.)
VCM1 (#4) The VCMD waveform signal conversion on the check board is
switched.
VCM2 (#5) Switches the VCMD waveform conversion value according to the
following list:
For rotary type motor
VCM2 VCM1 Number of velocity commandrevolution/5 V
0
0
1
1
0
1
0
1
0.9155 min
-1
14 min
-1
234 min
-1
3750 min
-1
For linear motor (P in the table below represents a scale signal pitch.)
VCM2 VCM1 Number of velocity commandrevolution/5 V
0
0
1
1
0
1
0
1
0.00375 × P m/min
0.06 × P m/min
0.96 × P m/min
15.36 × P m/min
[Reference item] Item (5) in Appendix I