4.SERVO FUNCTION DETAILS B-65270EN/05
- 284 -
(1) For activating phase adjustment, set the parameter below.
• For Series 9096, 90B0, 90B6, 90B5, or 90B1
1726 (FS15i)
For internal data measurement
2115 (16i)
Series 9096:
320 for an odd-numbered axis, 960 for an even-numbered axis
Series 90B0, 90B1, 90B5, or 90B6:
320 for an odd-numbered axis, 2368 for an even-numbered axis
• For Series 90D0 or 90E0
- For internal data measurement
2115 (FS30i)
Set 0.
- For internal data measurement
2151 (FS30i)
Series 90D0:
532 for an odd-numbered axis, 660 for an even-numbered axis
Series 90E0:
No. 1023 = (4n + 1) axis: 532
No. 1023 = (4n + 2) axis: 660
No. 1023 = (4n + 3) axis: 6676
No. 1023 = (4n + 4) axis: 6804
(n=0,1,2,…)
• Common to all series
After making the settings above, activating phase data is
output to Display No. 353 on the CNC diagnosis screen.
Note that display data = 256 on the diagnosis screen
corresponds to an activating phase of 360 degrees. The
following expression is used for output unit conversion to
an activation phase [degrees]:
Activating phase [degrees] =
(Value of DGN No. 353) × 360/256
(2) Turn off the power to the CNC and servo amplifier.