4.SERVO FUNCTION DETAILS B-65270EN/05
- 342 -
Table 4.18.6(a) Example of setting (1)
Synchronous axis Tandem axis Motor name SPPCHG Preload value
Main X
m
0 +
Master
Sub X
2
-
Main X
3
1 -
Slave
Sub X
4
+
Another example is given below.
Table 4.18.6(b) Example of setting (2)
Synchronous axis Tandem axis Motor name SPPCHG Preload value
Main X
m
1 -
Master
Sub X
2
+
Main X
3
0 +
Slave
Sub X
4
-
Gea
box
Sub-
motor
Main
moto
Gea
box
Sub-
motor
Gea
box
Gea
box
Main
motor
Slave side
Master side
Pinion
Rack
X2
Xm
X4
X3
Tandem
Tandem
Synchronous
control
Fig. 4.18.6 (e) Synchronous tandem control
(4) Checking whether the full preload function is operating normally
• Observe Tcmd on the main- and sub-axes with the check board.
The results are output to ch2 (main axis) and ch4 (sub-axis).
• After adjusting the damping compensation gain to 0, apply an
acc./dec. command. If the Tcmd value on the main side is
positive, and the Tcmd value on the sub-side is negative, the full
preload function is operating normally (when SPPCHG = 0).