4.SERVO FUNCTION DETAILS B-65270EN/05
- 220 -
If this overshoot compensation function is used, it is possible to
prevent overshoot so that the relationship between machine static
and non–static friction and TCMD2 satisfies <1>, however the
torque TCMD during machine stop is
TCMD2 = 0
the servo rigidity during machine stop is insufficient and it is
possible that there will be some unsteadiness at ±1 pulse during
machine stop.
There is an additional function to prevent this unsteadiness in the
improved type overshoot prevention function and the status of
the torque command at that time is shown in (iv).
(iv) Torque command when the improved type overshoot
compensation is used
Function bit
OVSC = 1 (Overshoot compensation is valid)
Parameter
PK3V: around 32000 (Incomplete integral coefficient)
OSCTP: around 20 (Number of incomplete integral)
When overshooting with this parameter, try increasing the value of the
overshoot protection counter (OSCTP) by 10. Conversely, when there
is no overshooting, but unsteadiness occurs easily during machine stop,
decrease the overshoot protection counter (OSCTP) value by 10.
When overshoot protection counter (OSCTP) = 0 it is the same as
existing overshoot compensation.
TCMD1
TCMD2
Torque command (TCMD)
Static friction
Time
Non-static friction
This time constant
is fixed at the
PK3V value.
t3
TCMD3
Fig. 4.7 (g) Torque command (using improved type overshoot
compensation)
If this function is used, the final torque command is TCMD3. If the
parameter PK3V (t3) is fixed so that this value becomes less than the
non–static friction level, overshoot is nullified. Because torque
command is maintained to some degree during machine stop, it is
possible to decrease unsteadiness during machine stop.