B-65270EN/05 2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS
- 33 -
RCNCLR (#1) The number of revolution is:
1: To be cleared. (To use the RCN220, RCN223, RCN723, or
RCN727, set the bit to 1.)
0: Not to be cleared.
This function bit is to be set in combination with the number of data
mask digits, described below.
2807 (FS15i)
Number of data mask digits
2394 (FS30i, 16i)
[Settings] 8. (To use the RCN223, RCN723, or RCN727)
5. (To use the RCN220)
The value to be set in this parameter depends on the detector. At
present, only the above detectors require clearing the speed data.
This parameter is to be set in combination with RCNCLR, described
above.
NOTE
The speed data of the RCN220, RCN223,
RCN723, or RCN727 is maintained while the power
to the separate detector interface unit is on. The
data, however, is cleared when the unit is turned
off. Since the speed data becomes undetermined
depending on where the power is turned off, it is
necessary to make a setting to clear the speed
data. In addition, for this reason, the RCN220,
RCN223, RCN723, and RCN727 cannot be used
with a linear axis.
When using the RCN220, set the parameters for the flexible feed gear
and the number of position pulses according to the setting method
described in the previous item, "Parameter setting for the serial output
type rotary encoder".
The following explains how to calculate the parameter values when
the RCN223, RCN723, or RCN727 is used.
[Flexible feed gear]
Parameters Nos. 1977 and 1978 (Series 15i) or Nos. 2084 and 2085
(Series 30
i, 16i, and so on)
Flexible feed gear (N/M) =
(Amount of table movement [deg] per detector revolution) /
(detection unit [deg]) / 8,000,000
For the RCN223, RCN723, and RCN727, the number of pulses per
detector turn is assumed to be eight million for calculation.
For the RCN727, when the detection unit is set to 1/8,000,000
revolution or less, the flexible feed gear may be set to up to 8/1. (If the
flexible feed gear is set to 8/1, the detection unit is 64,000,000 pulses
per revolution.)