B-65270EN/05 APPENDIX H.DETAILS OF HIGH-SPEED AND HIGH-PRECISION ADJUSTMENT
- 505 -
2739 (FS15i)
Disturbance input gain
2326 (FS30i, 16i)
[Default value] 0
[Valid data range] 0 to 7282 (to be set in Tcmd units; a value of 7282 corresponds to an
amplifier maximum current.)
Usually, specify 500 to apply vibration to the machine so that it will
sound lightly.
2740 (FS15i)
Disturbance input function start frequency (Hz)
2327 (FS30i, 16i)
[Valid data range] 1 to 2000
[Recommended value] 10
2741 (FS15i)
Disturbance input end frequency
2328 (FS30i, 16i)
[Default value] 200
[Valid data range] 1 to 2000 (Unit : Hz)
2742 (FS15i)
Number of disturbance input measurement points
2329 (FS30i, 16i)
[Default value] 3
[Valid data range] SWEPT SINE MODE 1 to 32767
Continuous sine mode Less than 0
Usually, specify 0 or greater to make the machine vibrate in swept
sine mode.
<2> Cautions
• Turn off the functions that work only when the machine is
at a halt, such as the variable proportional gain function in
the stop state and the overshoot compensation function.
• When measuring cutting characteristics, pay attention to
which function type, cutting or rapid traverse, is in use.
• Decrease the position gain to about 1000.
<3> How to use
The default disturbance input setting is the swept sine mode.
When the rising edge of the disturbance input bit is detected,
application of vibration is started. Vibration is automatically
stopped when sine sweeping from the start frequency to the end
frequency is completed. A reset or an emergency stop makes the
machine stop operating. After the emergency stop is released,
turning the function bit off and on again restarts disturbance
input.
• Example of setting
No2326 = 500 → gain = 500
No2327 = 0 → start frequency = 10 Hz
No2328 = 0 → end frequency = 200 Hz
No2329 = 0 → repetition = 3 times