I.SERVO CHECK BOARD OPERATING PROCEDURE APPENDIX B-65270EN/05
- 528 -
<2> To change the type of data to be measured and the unit of
conversion for it, press the F9 key on the main screen to display
the system setting screen.
Use numeric keys 0 to
3 to specify a signal to
be observed on each
measurement channel
and a unit conversion
for it.
Fig. I (f) System setting screen
Data output on CH1 to CH4 of the check board corresponds to
channels 0 to 3 on the SD software. To change the setting, press
numeric key 0 to 3. Select a data type (0: position, 1: velocity
command, 2: torque command, 3: rotation speed) from the display at
the bottom of the screen, then specify the unit of conversion for the
data.
Conversion values (except for position data) can be set up according
to descriptions in (5) to (8).
Table I (i) Meaning of measurement data conversion values and example setting
Type
Display at
the bottom
of the screen
Meaning of conversion
values
Example
Input
value
POS 1 pulse = X? Detection unit (in mm units) 1 µm 0.001
VCMD 5 V = X min
-1
?
What min
-1
corresponds to
VCMD of 5 V?
VCM2 = 1
VCM1 = 1
3750
(Note)
TCMD X Ap. Amp.? Maximum amplifier current (A) 40 A 40
SPEED
(number of
revolutions)
5 V = X min
-1
?
What min
-1
corresponds to
SPEED of 5 V?
-
Constantly
3750
(rotational
motor)
NOTE
To observe the VCMD signal as the number of
positional deviation pulses, input conversion values
listed in Tables I (c) to (e).
To exit the system setting screen, press the F10 key.