B–61863E/15
6. SCREEN OPERATION
(PMC–SB4/SB6/SC4/NB2)
STEP SEQUENCE FUNCTION
1021
The elapsed time of a step sequence program is displayed.
STPSEQ <<STATUS>> PROGRAM:(STEP SEQUENCE DEMO PROGRAM) MONIT RUN
STEP NO. STATUS ELAPSE MONITOR STEP NO. STATUS.
S0001( ) EXEC 1000000 T(1) OVER S0010(TILE ) EXEC
S0002( ) EXEC 100 T(3) S0011( )
S0003( ) EXEC 10000 T(4) S0012( )
S0004( ) 1000000 S0013( )
⋅ ⋅ ⋅ ⋅ ⋅
⋅ ⋅ ⋅ ⋅ ⋅
[ UP ] [ DOWN ] [ SEARCH ] [ RESET ] [ MONIT ]
Fig. 6.2.1 Time screen
Meaning of display
Display Contents
STEP NO. Step number
S0001 : Step number (123456) : symbol display
STATUS Step state
EXEC : Active space : Inactive
ELAPSE Actual elapsed time (per msec)
The time is increasing during active state.
MONITOR Monitor time
T (1) : monitoring time number
OVER : An elapsed time is over monitoring time
[UP] [DOWN] key
Scrolls the screen up or down, in units of pages, to display the
operation time of other steps. Acts in the same way as the page up
or down key.
[MONIT] key
Displays the screen used for setting the timer to monitor the operation
time. (See 6.3)
[SEARCH] key
Search and display the specified step number.
example) Display the S100 address.
Key in “100” and press the [SEARCH] key.
[RESET] key
For all of monitoring steps, the error status which occurred by the
monitoring function is canceled.
To cancel the status per steps, press the [DELETE] key on the monitor
time screen. (Please refer to 6.3 Monitor Time Screen below)
6.2
TIMER SCREEN
6.2.1
Time Screen