B–61863E/15
5. FUNCTIONAL INSTRUCTIONS
PMC SEQUENCE PROGRAM
359
(a) Control data address
Please set the top address of control data.
For the area specification data, 9bytes of continuous memory area in
the nonvolatile memory is necessary.
Control data+0
(basic
specification)
+1
+5
+9
Axis No.
or
Path No.
Boundary Point 1
(4bytes)
Boundary Point 2
(4bytes)
(1byte)
(1 : 1st Axis, 2 : 2nd Axis,...)
(1 : 1st Path–1st Axis
2 :2nd Path–1st Axis)
D In case of axis–No. specification
Please set axis–No. to select. (1 byte data of binary format)
(Example) Axis No.=1 : For machine coordinates of the 1st axis
Axis No.=2 : For machine coordinates of the 2nd axis
D In case of path specification (Power Mate–MODEL D two path
control)
Please set path–No. of axis to select. (1 byte data of binary format)
In the PMC–SB5/SB6 for the Power Mate i, control data can be used
under the following expanded specification. Generally, use of the
expanded specification offers faster operation. So it is recommended
that the expanded specification be used.
The control data requires 12 consecutive bytes in nonvolatile
memory.
Control data + 0
(expanded
specification)
+2
+3
+4
+8
+12
Fixed to 0
(2bytes)
Path specification
(1byte)
Axis number
(1byte)
Boundary point 1
(4bytes)
Boundary point 2
(4bytes)
(0 = path 1, 2 = path 2, ...)
(1 = first axis, 2 = second axis, ...)
5.74.4
Parameters