3. ADDRESS
B–61863E/15
PMC SEQUENCE PROGRAM
90
$
²This portion is replaced by an I/O link
connection unit.
I/ O Unit
Model A
I/ O Unit
Model A
(a)
I/ O Unit
Model A
I/ O Unit
Model A
I/ O Unit
Model A
I/ O Unit
Model A
CNC A CNC B
Consequently, when the I/O link connection unit is used, the connections
become as shown below.
I/ O Unit
Model A
I/ O Unit
Model A
I/O Link
connection unit
I/ O Unit
Model A
I/ O Unit
Model A
CNC A CNC B
The assignment data depends on what type of I/O unit is to be replaced
with an I/O link connection unit.
Occupied
address
Input unit name at the time of assignment Output unit name at the time of assignment
1 to 8 / V (V represents a number from 1 to 8.) / V (V represents a number from 1 to 8.)
16 OC02I OC02O
32 OC03I OC03O
When a connection unit that occupies 16–byte addresses is attached to the
input side in GROUP = 1, enter “1.0.1.OC02I
.”
NOTE
On the PMC–SB6/SB7 for Series 16i/18i/21i/160i/180i/
210i, when programming software supports the I/O Link
expansion, I/O Link connection unit can be assigned to the
I/O Link channel 2 area. To link the I/O Link channel 2
actually, the option of the I/O Link expansion is necessary.
Method of assignment:
Setting: