5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
308
This command reads up to 32 bytes of data via the window between PMC
and MMC. The data can be determined as required between the PMC
ladder program and MMC application program.
MMCWR
(SUB98)
ffff
Input data
length
address
ACT
W1
ffff
Input data
address
Fig. 5.49.2 MMCWR instrument format
Table 5.49.2 MMCWR coding format coding sheet
Step
number
Command
Address
No.
Bit No. Remarks
1 RD fff. f ACT
2 SUB 98 MMCWR command
3 (PRM) ffff Input data length address
4 (PRM) ffff. Input data address
5 WRT fff. f W1, processing completion
ACT=0 : The MMCWR function is not executed.
ACT=1 : The MMCWR function is executed. Hold ACT = 1 until
processing is completed and specify ACT = 0 immediately after
processing is completed (W1 = 1).
CAUTION
Stopping the ladder with ACT set to 1 issues WN03 on the
PMC alarm screen. In this case, the function command
cannot be executed continuously. After execution of the
function command, set ACT to 0.
5.49
MMCWR (READING
MMC WINDOW DATA)
(OTHER THAN
PMC–PA1/PA3)
5.49.1
Function
5.49.2
Format
5.49.3
Control Condition