B–61863E/15
B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
APPENDIX
1299
[Completion codes]
0 : The tool information was written successfully.
3 : The tool group number exceeded the range 1 to 512 or maximum
number of registered groups.
4 : The specified tool number is incorrect.
5 : The specified tool number is not registered to the specified tool
group.
6 : The tool life management option has not been added on.
[Output data structure]
Top address 0
2
4
6
8
(Function code)
231
(Completion code)
?
(See the explanation above.)
(Data length)
2
(Entered data)
(Data number)
N
(Entered data)
(Data attribute)
M
(Entered data)
Tool length offset number
(2 bytes)
14
12
The following table shows how the tool status changes before and after
this function is specified.
command Pre–command Status Post–command Status
clear
skip ( # )
skip ( # )
used ( * )
unused ( )
in use (@)
unused ( )
skip
unused ( )
in use (@)
used ( * )
skip ( # )
skip ( # )
skip ( * )