4. PMC PARAMETERS SETTING AND
DISPLAY (PMCPRM)
B–61863E/15
PMC OPERATION (CRT/MDI)
478
#7 DTBLDSP 0 : The PMC parameter data table control screen is
displayed.
1 : The PMC parameter data table control screen is
not displayed.
#6 ANASTAT
0 : In the function for displaying signal waveforms,
sampling starts when the [START] soft key is pressed.
1 : In the function for displaying signal waveforms,
sampling starts automatically when the power is
turned on.
* This bit is effective only for applicable models specified in 3.6,
“Function for Displaying Signal Waveforms (ANALYS),” in Part
II.
#5 TRCSTAT 0 : In the signal trace function, tracing starts when
the [EXEC] soft key is pressed.
1 : In the signal trace function, tracing starts
automatically when the power is turned on.
#4 MEMINP 0 : Data cannot be entered in the memory content
display function.
1 : Data can be entered in the memory content
display function.
* This bit is effective only for applicable models specified in 3.5,
“Display the Contents of Memory (M.SRCH),” in Part II.
#3 SELCTMDL 0 : The sequence program stored in ROM (EPROM)
is enabled.
1 : The sequence program stored in the RAM
module or ROM module (only for
PMC–SB2/SB3) is enabled.
* This bit enables either the EPROM module or ROM/RAM
module when both modules are provided. It is effective for the
PMC–SA1, SA2, SA3, SB, SB2, and SB3. (It is not effective for
the Series 20 or Series 16/18 MODEL–B.)
#2 AUTORUN 0 : In RAM operation, a sequence program is not
executed when the power is turned on.
1 : In RAM operation, a sequence program is
executed automatically when the power is turned
on (as in ROM operation).
* For the PMC of the Series 16/18 MODEL–B/C, Series
16i/18i/21i–MODEL A, and Power Mate i–D/H this bit has the
following meanings.
0 : The sequence program is executed automatically
when the power is turned on.
1 : The sequence program is executed when the
[RUN] soft key is pressed.
#1 PRGRAM 0 : The built–in programmer function is not
operated.
(The programmer menu is not displayed, either.)
1 : The built–in programmer function is operated.