B–61863E/15
6. SCREEN OPERATION
(PMC–SB4/SB6/SC4/NB2)
STEP SEQUENCE FUNCTION
1027
Meaning of display
Display Contents Display by [ZOOM] key
[V] Sxxx Initial step Ladder diagram
V Sxxx Step Ladder diagram
V] Sxxx Block step Step sequence diagram
+ Pxxx Transition Ladder diagram
Selective sequence Cannot zoom.
Simultaneous sequence Cannot zoom.
L2
Jump Cannot zoom.
L2 Label Cannot zoom.
Pxxx means the subprogram number.
[ZOOM] key
To display the contents of a program, position the cursor to the
program number and press the [ZOOM] key. The step sequence
diagram (Fig. 6.4.2 (b)) or ladder diagram (Fig. 6.4.3 (c)) is
automatically displayed according to the type of the program.
[MAIN] key
Press the [MAIN] key to return to the program configuration list.
[CHANGE] key
Press the [CHANGE] key to list the subprograms referenced in
the step sequence program.
[P–ADRS/P–SYMB/S–ADRS/S–SYMB] key
Displays the addresses specified with steps and transitions, using
addresses or symbols, if symbols have been assigned.
And the display of steps is changed to display the S addresses or
P addresses.
Press the [P–ADRS] key to display the addresses of P addresses.
Press the [P–SYMB] key to display the symbols of P addresses.
Press the [S–ADRS] key to display the addresses of S addresses.
Press the [S–SYMB] key to display the symbols of S addresses.
(3) Displaying the list screen
While the step sequence screen is displayed and press the [CHANGE]
key, a list screen of the subprograms referenced in this step sequence
program is displayed.
LADDER <<LIST>> PROGRAM:(STEP SEQUENCE DEMO PROGRAM) MONIT STOP
S0001 P0001 (ROTATE) ROTATE THE WORK TIP
V] P0001 V] P0002 V] P0004 V] P0005 V] P0006 V] P0007
V P0008 V P0009 V P0014 V P0015 V P0016 V P0017
V P0021 V P0022 V P0024 V P0025 V P0026 V]P0027
⋅⋅⋅⋅ ⋅ ⋅
⋅⋅⋅⋅ ⋅ ⋅
V P0101 V P0202 V]P0304 V]P0405 V]P0406 V]P0407
[ UP ] [ CHANGE ] [ ] [ P–ADRS ] [ ZOOM ]
[ZOOM] soft key
To display a program, position the cursor to the program number
and press the [ZOOM] key. The step sequence screen (Fig. 6.4.2
(b)) or ladder screen (Fig. 6.4.3 (c)) is automatically displayed