5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
204
ANDs logical multiplication data and input data, and outputs the results
to a specified address. Can also be used to remove unnecessary bits from
an eight–bit signal in a specific address, etc.
(Logical multiplication data) (Input data) to a specified address
The input data is one byte (eight bits).
0 0 0 0 0 0
7654 32
0
1
0
0
Input data
Low–order four–bit logical
multiplication data
fff fffff
High–order four–bit
logical multiplication data
Logical
multiplication data
Fig.5.16.2 shows the expression format and Table 5.16.2 shows the
coding format.
MOVE
(SUB 8)
ACT
ffff. f
(1)
ffff
Control condition
(2)
ffff
(3)
ffff
(4)
ffff
Output address
Input data address
Low–order 4–bit logical multiplication data
High–order 4–bit logical multiplication data
Fig. 5.16.2 Move instruction format
Table 5.16.2 Coding for Fig.5.16.2
Coding sheet Memory status of control condition
Step
Number
Instruc-
tion
Address
No.
Bit No. Remarks ST3 ST2 ST1 ST0
1 RD fff . f ACT ACT
2 SUB 8 MOVE instruction
3 (PRM) ffff High–order 4–bit logical
multiplication data (1)
4 (PRM) ffff Low–order 4–bit logical
multiplication data (2)
5 (PRM) ffff Input data address (3)
6 (PRM) ffff Output data address (4)
5.16
MOVE
(LOGICAL PRODUCT
TRANSFER)
5.16.1
Function
5.16.2
Format