3. PMC I/O SIGNAL DISPLAY AND
INTERNAL RELAY DISPLAY
(PMCDGN)
B–61863E/15
PMC OPERATION (CRT/MDI)
442
EXEC : Starts reading signals
CAUTION
1 Pressing the [EXEC] key again clears the results of the
previous trace.
If the trace parameters are not set correctly, the trace is not
performed.
When signals are being sampled using the function for
displaying signal waveforms, the trace is not performed.
2 The result data of the trace is stored latest 256-byte. If the
power is turned off, the results of the trace are cleared.
3 Signals R9000 to R9007 cannot be traced.
4 A signal is traced at intervals of 8 ms. If the signal changes
within 8 ms, the changed signal state cannot be traced.
5 When the trace address type is specified as a physical
address, specify an effective memory address. If an
ineffective address is specified to execute the trace, a
system error may occur.
STOP : Stops reading signals.
PMC SIGNAL TRACE MONIT RUN
TRACE MODE : 1
(0:1BYTE/1:2BYTE/2:WORD)
1ST TRACE ADDRESS CONDITION
ADDRESS TYPE : 1 (0:PMC /1:PHY)
ADDRESS : FFE480
MASK DATA : 11
2ND TRACE ADDRESS CONDITION
ADDRESS TYPE : 0 (0:PMC /1:PHY)
ADDRESS : Y0
MASK DATA : FF
[T.DISP] [ EXEC ] [ ] [ ] [ ]
Fig. 3.4.3 Trace parameter setting screen
3.4.3
Starting or Stopping
the Trace Function