B–61863E/15
8. FUNCTIONS FOR DISPLAYING MEMORY
AREAS AND DEBUGGING
THE PROGRAM (MONIT)
PMC PROGRAMMER (CRT/MDI)
609
To display the soft key [MONIT] in the PMC main menu screen, set
”PROGRAMMER
ENABLE” to ”YES” in the setting screen. When pushing the soft key
[MONIT]–>[ONLINE], the online setting screen is displayed. (Fig.
8.5.1)
1. Case of connection by RS–232C (FANUC LADDER–II, FANUC
LADDER–III)
(1)Check that ”NOT USE” is selected at the ”RS–232C” item.
(2)Set the parameter of ”CHANNEL” and ”BAUD RATE”.
(3)Move the cursor to the ”RS–232C” item with Up or Down Cursor
key.
(4)Select ”USE” with Left or Right Cursor key.
2. Case of connection by Ethernet (FANUC LADDER–III, Ladder
Editing Package)
(1)Move the cursor to the ”HIGH SPEED I/F” item with Up or Down
Cursor key.
(2)Select ”USE” with Left or Right Cursor key.
3. Case of connection by HSSB (Ladder Editing Package)
(1)Move the cursor to the ”HIGH SPEED I/F” item with Up or Down
Cursor key.
(2)Select ”USE” with Left or Right Cursor key.
NOTE
1 When both ”RS–232C = USE” and ”HIGH SPEED I/F =
USE” are selected, the PMC system will communicate with
the application which is connected at first. If PMC system is
already connecting with an application, it can not connect
with other applications.
2 When you use the online function by Ethernet, the setting
of Ethernet parameters at CNC is necessary in advance.
3 Loader control function can not connect with FANUC
LADDER–III or Ladder Editing Package by Ethernet.
8.5.2.1
How to set at PMC
Screen