B–61863E/15
3. PMC I/O SIGNAL DISPLAY AND
INTERNAL RELAY DISPLAY
(PMCDGN)
PMC OPERATION (CRT/MDI)
471
(2) Clearing OVERRIDE
By using the [OVRRST] soft key, clear the OVERRIDE state of the
desired bit/byte.
This operation returns the state of a signal to the state existing before
OVERRIDE setting.
(a) Clearing OVERRIDE on a bit–by–bit basis
Position the cursor to the desired bit, then press the [OVRRST]
soft key.
PMC SIGNAL FORCING OVERRIDE MONIT RUN
NO.76543210
X0000 000001>0 00
Then, the display changes as shown below.
PMC SIGNAL FORCING OVERRIDE MONIT RUN
NO.76543210
X0000 000001 00
(b) Clearing OVERRIDE on a byte–by–byte basis
Position the cursor to the desired byte, then press the [OVRRST]
soft key.
PMC SIGNAL FORCING OVERRIDE MONIT RUN
NO.76543210
X0000 1>0 0>1 1>0 0>0 1>0 1>1 1>0 0>1
Then, the display changes as shown below.
PMC SIGNAL FORCING OVERRIDE MONIT RUN
NO.76543210
X0000 10101110
(c) Clearing OVERRIDE for all X and Y areas
Press the [INIT] soft key. Then, the message ”CLEAR
OVERRIDES OK?” is displayed.
By using the soft key [EXEC]/[CANCEL], execute or cancel the
clearing of OVERRIDE.