B–61863E/15
5. LADDER DIAGRAM EDITOR
FUNCTION (PMC–SB7)
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
921
Alarm number ContentsFaulty location/corrective action
JMPB OVER COM BORDER JMPB and its destination must have
same COM/COME status. Review
range of JMPB and COM range, to ad-
just not to overlap with each other: it is
possible that one range includes the
other completely.
JMPB and its destination differ in
COM/COME status.
JMPB OVER LEVEL JMPB can only jump to the same pro-
gram level, or within a subprogram. If
the JMPB is unnecessary, remove it. If
LBL for the JMPB is missing, add it in
proper position. If it should be JMPC,
correct it.
JMPB jumps to different program level.
LBL FOR JMPB NOT FOUND If JMPB is unnecessary, remove it. If
LBL is missing, add it in proper posi-
tion.
Can not find proper LBL for JMPB.
JMPC IN BAD LEVEL JMPC is used to jump from a subpro-
gram to level 2. If the JMPC is unnec-
essary, remove it. If it should be JMPB
or JMP, correct it.
JMPC is used in other than subpro-
gram.
LBL FOR JMPC NOT FOUND If JMPC is unnecessary, remove it. If
LBL is missing, add it in proper posi-
tion: JMPC jumps into level 2. If it
should be JMPB or JMP, correct it.
Can not find proper LBL for JMPC.
LBL FOR JMPC IN BAD LEVEL JMPC is used to jump from a subpro-
gram to level 2. If the JMPC is unnec-
essary, remove it. If another LBL of
same L–address that the JMPC is in-
tended to jump exists in the subpro-
gram, assign different L–address to
these two LBLs. If it should be JMPB
or JMP, correct it.
Destination of JMPC is not level 2.
JMPC INTO COM LBL for JMPC must be located out of
any COM and COME pair. If the JMPC
is unnecessary, remove it. If the LBL is
located wrong, move it to correct posi-
tion. If the L–address of JMPC is
wrong, correct it.
JMPC jumps to LBL between COM
and COME.
JMPE WITHOUT JMP If JMP is missing, add it in proper posi-
tion. If the JMPE is unnecessary, re-
move it.
There is no JMP that corresponds to
this JMPE.
TOO MANY LBL Remove unnecessary LBLs. If this er-
ror still occurs, adjust the construction
of program to use less LBLs.
There are too many LBLs.
DUPLICATE LBL If some of these LBLs are unneces-
sary, remove them. If all of these LBLs
is necessary, assign other L–address-
es to them to make all LBLs unique.
Same L–address is used in plural
LBLs.
OVERLAPPED SP If SP is missing, add it in proper posi-
tion. If the SPE is unnecessary, re-
move it.
There is no SP that corresponds to
this SPE.