B–61863E/15
5. LADDER DIAGRAM EDITOR
FUNCTION (PMC–SB7)
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
919
Messages that may be displayed during PMC program editing
Alarm number Faulty location/corrective action Contents
OVERLAPPED COM If COME is missing, add it in proper
position. If the COM is unnecessary,
remove it.
There is no COME that corresponds to
this COM.
END IN COM
END1 IN COM
END2 IN COM
If COME is missing, add it in proper
position. If COM is unnecessary, re-
move it.
END,END1,END2, or END3 is found
between COM and COME.
JMPE IN COM JMPE and corresponding JMP must
have same COM/COME status. Re-
view JMP range and COM range, to
adjust not to overlap with each other: it
is possible that one range includes the
other completely.
JMPE is found between COM and
COME, and JMP and corresponding
JMPE have different COM/COME sta-
tus.
SP/SPE IN COM If COME is missing, add it in proper
position. If the COM is unnecessary,
remove it.
SP or SPE is found between COM and
COME.
COME WITHOUT COM If COM is missing, add it in proper
position. If the COME is unnecessary,
remove it.
There is no COM that corresponds to
this COME.
DUPLICATE CTR NUMBER
(WARNING)
If some of them are unnecessary, re-
move them. If all of them are neces-
sary, assign other number to parame-
ter of them to make them unique. (If
two or more instructions with same pa-
rameter number will never be active
simultaneously at one time, the Ladder
program has a possibility to work cor-
rectly, however, it is recommended
from safety and maintenance points of
view, that all these instructions should
have different parameter number with
each other.)
Plural CTRs have the same number as
their parameter. (This is warning.)
ILLEGAL CTR NUMBER If unnecessary, remove it. Assign cor-
rect number not to exceed the maxi-
mum number defined by each PMC
model.
CTR has parameter number that is out
of range.
5.10
ALARM MESSAGE
AND
COUNTERMEASURE