L. MIGRATION OF LADDER PROGRAMS
BETWEEN DIFFERENT MODELS
B–61863E/15
APPENDIX
1538
D Action for modifications of library function specification
The following functions in ”III PMC LIBRARY” are not available
to Series 16i/18i/21i–B because PMC memory is extended for
PMC–SB7 on Series 16i/18i/21i–B and because there are the
sections which these conventional functions can not access.
*5.1 pl_memc, pl_mems, pl_meml, pl_memuc, pl_memus,
pl_memul
5.2 pl_membrd
5.3 pl_membwrt
Please use following functions instead of them.
5.4 pl_memc2, pl_mems2, pl_meml2, pl_memuc2,
pl_memus2, pl_memul2
5.5 pl_membrd2
5.6 pl_membwrt2
To keep the compatibility of source program according to each
PMC model having the different PMC addresses, it is
recommended to use above functions from 5.4 to 5.6.
D Action for different operation timing
With Series 16i/18i/21i–B, the ladder is made faster when
compared with Series 16i/18i/21i–A. So, the C language
application depending on the ladder program execution speed may
not operate as it is. Check the operation design.
(11) NC Parameter number 24 (PMC–SA1/SB7)
You can enable and disable the online connection for Ethernet, HSSB
and RS–232C by NC parameter No.24 without setting on the PMC
online monitor setting screen.
When you used the Ladder Editing Package or the FANUC
LADDER–III on the Open CNC or the system with the Ethernet
option on the 16i/18i/21i–A, the high speed I/F (HSSB or Ethernet)
has been effective with the initial value ”0” automatically.
On 16i/18i/21i–B, the initial value does not make ”High Speed I/F”
effective.
The 16i/18i/21i–B has the Ethernet function as a basic, and it is
impossible to distinguish by the option. So, the initial value is
modified.
If you use the Ladder Editing Package or FANUC LADDER–III
(through the Ethernet), please set this parameter to ”10”, or set this
parameter to ”0” and set ”HIGH SPEED I/F ” to ”USE” in the online
setting screen. If you do not use these software, please keep the initial
value.