M. ALARM MESSAGE LIST
B–61863E/15
APPENDIX
1556
Message Contents and solution
ER33 SLC ERROR
or
ER33 SLC ERROR(CH2)
The LSI for I/O Link is defective.
Display of ”CH2” means the defectiveness of I/O Link channel 2.
(solution) Please exchange the module of PMC engine.
ER34 SLC ERROR(xx)
or
ER34 SLC ERROR(CH2 xx)
The communication with the DI/DO units of the xx group of I/O Link failed.
Display of ”CH2” means the xx group of I/O Link channel 2.
(solution) Please confirm the connection of the cable connected to the
DI/DO units of the xx group.
Please confirm that the DI/DO units turned on earlier than CNC
and PMC. Or, please exchange the main CPU board.
ER35 TOO MUCH OUTPUT DATA IN GROUP
(xx)
or
ER35 TOO MUCH OUTPUT DATA (CH2 xx)
The amount of the output data in the xx group of I/O Link exceeded the
max. The data, which exceed 32 bytes, become ineffective.
Display of ”CH2” means the xx group of I/O Link channel 2.
(solution) Please refer to the following for the number of the data for each
group.
”FANUC I/O Unit–MODEL A connecting and maintenance
manual” (B–61813E) ”FANUC I/O Unit–MODEL B connecting
manual”(B–62163E)
ER36 TOO MUCH INPUT DATA IN GROUP (xx)
or
ER36 TOO MUCH INPUT DATA (CH2 xx)
The number of the input data in the xx group of I/O Link exceeded the
max. The data, which exceed 32 bytes, become ineffective.
Display of ”CH2” means the xx group of I/O Link channel 2.
(solution) Please refer to the following for the number of the data for each
group.
”FANUC I/O Unit–MODEL A connecting and maintenance
manual” (B–61813E) ”FANUC I/O Unit–MODEL B connecting
manual”(B–62163E)
ER38 MAX SETTING OUTPUT DATA OVER (xx)
or
ER38 MAX SETTING OUTPUT DATA (CH2 xx)
The assignment data for a group exceeds 128 bytes.
(The assignment data of output side of xx group or later become
ineffective.)
Display of ”CH2” means the xx group of I/O Link channel 2.
(solution) Please reduce the assignment data to 128 bytes or less for the
number of the output data of each group.
ER39 MAX SETTING INPUT DATA OVER (xx)
or
ER39 MAX SETTING INPUT DATA (CH2 xx)
The assignment data for a group exceeds 128 bytes.
(The assignment data of input side of xx group or later become infective.)
Display of ”CH2” means the xx group of I/O Link channel 2.
(solution) Please reduce the assignment data to 128 bytes or less for the
number of the input data of each group.
ER48 STEP SEQUENCE TIME OVER (xxH) Time–out occurred during step sequence processing. For details, see
IV–6.2.2.
ER98 ILLEGAL LASER CONNECTION The I/O unit group for the laser does not match the assignment data.
(solution) Make sure that the actual I/O unit configuration matches the
assignment data in the ladder.
ER99 X, Y96–127 ARE ALLOCATED Laser I/O assignments are assigned to X96 to X127 and Y96 to Y127
when the laser I/O link is supported.
(solution) Delete I/O assignment data of X96 to X127 and Y96 to Y127.