1. SEQUENCE PROGRAM
CREATING PROCEDURE
B–61863E/15
PMC SEQUENCE PROGRAM
32
Table 1.2 Summary of specification of ladder program (3)
Model
Series
PMC–
NA
(4046)
PMC–
NB
(4047)
(4048)
PMC–
NB2
(4048)
PMC address Interfaces between the PMC and CNC (F and G)
Incompatible
Interfaces between the PMC and machine
(X and Y)
Compatible
Subprogram, label (P and L)
Not
provided
Provided
Others (R, A, C, K, D, T)
Compatible (Note 1)
Ladder ROM format (object)
Incompatible (Note 2)
program
compatibility
Source format (mnemonic)
Compatible (Note 3)
System Divided system
Provided Not provided
Undivided system
Not
provided
Provided
Structuring Subprogram
Unusable Usable
Step sequence
Unusable Usable
Basic commands
Compatible
Function END3 (SUB48)
Provided
commands
DISP (SUB49)
Provided Not provided
COM Coil count spesification
Provided Not provided
(SUB9)
COME (SUB29) specification
Provided
JMP Coil count specification
Provided Not provided
(SUB10)
JMPE (SUB30) specification
Provided
FNC9X (SUB9X)
Provided
LIBRY (SUB60), LEND (SUB61)
Provided Not provided
MMCWR (SUB98), MMCWW (SUB99)
MMC3R (SUB88), MMC3W (SUB89)
MOVB (SUB43), MOVW (SUB44)
MOVN (SUB45)
DIFU (SUB57), DIFD (SUB58)
AND (SUB60), OR (SUB61)
NOT (SUB62), EOR (SUB59)
Not
provided
Provided
Function
command
(for structured
S Command for subprogram
END (SUB64) , CALL (SUB65) , CALLU
(SUB66) , SP (SUB71) , SPE (SUB72)
Not
provided
Provided
programming)
S Extended jump command
JMPB (SUB68) , JMPC (SUB73) , LBL (SUB69)
Not
provided
Provided
NOTE
1 Management of internal relay address and that of datatable
are different between the PMC–NB/NB2 and the PMC–NA.
2 The same ROM cannot be shared by different models.
The ROM must be rewritten using the offline programmer.
3 The data can be converted by outputting in the source
format and then inputting again.
Moreover, a part of functional instruction is not compatible