B–61863E/15
3. DISPLAYING PMC INPUT/OUTPUT
SIGNALS AND INTERNAL RELAY
(PMCDGN)
PMC–NB6 MANIPULATION
673
Error message Meaning and solution
GROUP NUMBER
IS TOO LARGE
Meaning:
Too large Group number is input.
Solution:
Input Group Number below 16.
BASE NUMBER IS
TOO LARGE
Meaning:
Too large Base number is input.
Solution:
I/O Unit–B (##,#1–#10): Input Base number 0
Other I/O Unit: Input 0 or 1.
SLOT NUMBER IS
TOO LARGE
Meaning:
Too large Slot number is input.
Solution:
I/O Unit–B: Input Slot number below 31
Other I/O Unit: Input Slot number below 11
SLOT NUMBER IS
TOO SMALL
Meaning:
Too small Slot number is input.
Solution:
I/O Unit–B: Input Slot number 0 or above
Other I/O Unit: Input Slot number above 0
I/O UNIT NAME
MISMATCH
Meaning:
I/O Unit for X is allocated to Y address or I/O Unit for Y
is allocated to X address.
Solution:
Confirm the I/O Unit Name and the address
ILLEGAL I/O UNIT
NAME
Meaning:
I/O Unit name is not correct.
Solution:
Input correct name described at Chapter I.3.2 Table
3.2.2.
NOT ENOUGH
SPACE
Meaning:
There is no enough space for the size of I/O Unit you
will allocate.
Meaning:
This message is displayed also in case you will allo-
cate to the address in which other I/O Unit has been
allocated.
Solution:
Re–Input the allocation after you delete the allocation
under the cursor and make space.
3.6.3.2