6. NONVOLATILE MEMORY
B–61863E/15
PMC SEQUENCE PROGRAM
368
(1) Introduction
PMC sequence control sometimes requires a sizable amount of
numeric data (herein after referred to as data table. If contents of such
data table are free to set or to read, they can be used as various PMC
sequence control data, such as tool numbers of tools on the ATC
magazine.
Each table size can be set optionally in the memory for data table, and
1-, 2-, or 4-byte binary or BCD format data can be used per each table,
thus consigning a simple-to-use table.
Data in the data table can be set in the nonvolatile memory or
displayed via the CRT/MDI panel.
Data set in the data table can also be easily read or written by the
sequence program using function instructions as data search
(DSCHB), or index modification data transfer (XMOVB).
NOTE
For details of the usable range, see I–3.
(2) Configuration of the PMC data table and notes on programming
(a) Configuration of the data table
PMC data table consists of table control data and data table. Table
control data control the size and data format (BCD or binary) of
the tables.
This table control data must first be set from CRT/MDI before
preparing data table. In the sequence program, the table control
data cannot be read or written. When the contents of the
nonvolatile memory are read or written using the Floppy Cassette,
the table control data is read or written together. Fig 6.3 (a) is a
general configuration of the data table, and Fig 6.3 (b) is a detailed
configuration of the data table. Also refer to 3.7 for data table
configuration.
(b) Data table head address
If the data table starts from an odd address, for example, when a
data table is created with an odd number of one-byte data, the
DSCHB instruction operates slower than when the data table
starts from an even address. It is recommended that the starting
address of a data table be an even number.
6.3
PMC DATA TABLE