1023
Operation time limits can be specified for a step sequence program. Up
to eight steps can be monitored.
STPSEQ<<MONITOR>> PROGRAM:(STEP SEQUENCE DEMO PROGRAM) MONIT RUN
NO. STEP NO. ELAPSE MONITOR
T(1) S0001( ) 1000000 2000
T(2) S0010(MOVE ) 100 1000
T(3) S0002( ) 100 2000
T(4) S0003( ) 10000 20000
T(5)
T(6)
T(7)
T(8)
[ DELETE ] [ ] [ ] [ ] [ ]
Fig. 6.3 monitor time screen
Meaning of display
Display Meaning
NO. Monitor time number
T (1) : means monitor time 1.
STEP NO. Step number
S0001 : Step number (123456) : symbol display
ELAPSE Actual elapsed time (per msec)
The time is increasing during active state.
MONITOR Monitor time (per msec)
[DELETE] key
Delete the definition of monitor time.
Operation
Definition of monitor
(1) Position the cursor at the input position and input a step
(or symbol).
NO. STEP NO. ELAPSE MONITOR
T(1) S0001( ) 1000000 2000
T(2) S0010(MOVE )
Key in “MOVE” and push [INPUT] key.
(2) Position the cursor at the input position and define a monitor
time.
NO. STEP NO. ELAPSE MONITOR
T(1) S0001( ) 1000000 2000
T(2) S0010(MOVE ) 1000 100
Keyin “100” and push [INPUT] key.
6.3
MONITOR TIME
SCREEN