B–61863E/15
B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
APPENDIX
1159
[Completion codes]
0 : Parameter data has been read normally.
3 : The parameter number specified for reading is invalid.
4 : The specified data attribute is invalid because it is neither 0, –1,
nor a value 1 to n (n is the number of axes).
6 : Although a certain option, such as the pitch error compensation
option, is required for the data of the parameter number specified
for reading, it is not provided.
[Output data structure]
Top address + 0
2
4
6
8
10
(Function code)
17
(Completion code)
?
(See the explanation of
the completion codes.)
(Data length)
L
(L = 1, 2, 4, 1*n, 2*n, 4*n)
(Data number)
N
(N = Input data)
(Data attribute)
M
(M = Input data)
Parameter data
Parameter–dependent form
Value
L = 1: Bit or byte parameter
L = 2: Word parameter
L = 4: Double word parameter
When no axis or one axis is specified
When all axes are specified
L = 1*n : Bit or byte parameter
L = 2*n: Word parameter
L = 4*n: Double word parameter
CAUTION
For the SB5/SB6/SB7, macro executor parameters 9000 to
9011 cannot be read.