B–61863E/15
4. PMC BASIC INSTRUCTIONSPMC SEQUENCE PROGRAM
125
(1) Format
(Address)
Address number
Bit number
(2) Inverts the status of a signal at a specified address and set it in ST0.
(3) Is used when beginning coding with contact B (
). See the ladder
diagram of Fig. 4.1.2 and entries in the coding sheet of Table 4.1.2
for an example of using the RD.NOT instruction.
(4) The signal read by the RD.NOT instruction may be any contact B
entered as the logical condition of one coil.
A C
W1
D G
W2
B
G5.1
E
X4.2
F
Y10.7
R10.5
R210.2
R210.1
R1.1 F3.3F2.2
Fig. 4.1.2 Ladder diagram
Table 4.1.2 Coding for Fig. 4.1.2
Coding sheet Status of operating result
Step
Number
Instruction Address No. Bit No. Remarks ST2 ST1 ST0
1 RD. NOT R1 . 1 A A
2 AND . NOT F2 . 2 B A.B
3 AND . NOT F3 . 3 C A@B@C
4 WRT R210 . 1 W1 output A@B@C
5 RD. NOT G5 . 1 D D
6 OR . NOT X4 . 2 E D+E
7 OR Y10 . 7 F D+E+F
8 AND R10 . 5 G (D+E+F)@G
9 WRT R210 . 2 W2 output (D+E+F)@G
4.1.2
RD. NOT