5. EDITING OF SEQUENCE
PROGRAM (EDIT)
B–61863E/15
PMC PROGRAMMER (CRT/MDI)
546
Set and delet the address of each module in I/O unit as follows. The
relation between these functions and soft keys is as shown in the
following figure.
RUN EDIT I/O
TITLE LADDER SYMBOL MESAGE
NEXT
RETURN
SYSPRM MONIT
SYSPRM MODULE
INPUT SEARCH DELETE NXT.CH
RETURN
IOSTRT
NEXT
PRV.CH
(Note 1) (Note 1)
(Note 1)These soft keys are available, when editing sequence program
is allowed to assign to the I/O Link channel 2.
Fig. 5.3 Address setting for I/O unit
(1) Address setting for each module
1 Press the soft key [MODULE].
The following module address setting screen is displayed.
2 Move the cursor to the address to be set, and input data in the
order of GROUP, BASE, SLOT, and NAME and press
INPUT key. Input a dot (.) as a delimiter of each data.
Example) When setting the AID16A module with group = 0,
base = 0, and slot = 5
0. 0. 5. ID16A
Table 3.2.2 in Section I–3.2 lists the necessary names for the
NAME column.
3 Set all data of the module employed to aimed addresses by
using the cursor key and page key.
5.3
I/O UNIT ADDRESS
SETTING (MODULE)