B–61863E/15
3. PMC I/O SIGNAL DISPLAY AND
INTERNAL RELAY DISPLAY
(PMCDGN)
PMC OPERATION (CRT/MDI)
451
Pressing the “²” key shifts traced data to the left. Pressing the “³”
key shifts traced data to the right.
PMC SIGNAL ANALYSIS(SCOPE) MONIT RUN
SAMPLING TIME : 10 CONDITION : 1
TRIGGER ADDRESS:*ESP TRIGGER MODE: 1
ED0
ED1
ED2
ED3
ED4
ED3
-256 0(MSEC)
[SGNPRM] [START ] [T.SRCH ] [ADRESS ] [ ]
START/STOP ADRESS/SYMBOL
Fig. 3.6.4 Screen displaying signal diagnosis
Since parameter and sampling data is stored in nonvolatile memory, data
is retained when the power is turned off.
Data sampling can be started automatically, immediately after power–on,
by setting sampling parameters and setting the keep relay beforehand.
The keep relay setting method depends on the PMC model. See Section
4.3.3.
3.6.5
Reading Signals
Automatically at Power
on