3. ADDRESS
B–61863E/15
PMC SEQUENCE PROGRAM
104
(5) R9100 to R9117 (Interface area for the FNC9x functional
instruction) (PMC–SC3/SC4/NB/NB2 only)
The area is provided as an interface between the FNC9x functional
instruction to be executed and a desired function.
R9100
R9101
R9102
R9103
R9104
R9105
Contents of the command
to be executed
Data output when the
processing is completed
Addresses of the control data for SUB90
Addresses of the control data for SUB91
97 96 95 94 93 92 91 90
97 96 95 94 93 92 91 90
76543210
R9116
R9117
Addresses of the control data for SUB97
(6) R9091 (System timer)
4 signals can be used as system timer.
The specifications of every signal are as following.
76543210
R9091
always OFF
always ON
Cyclic signal of 200 ms
(104 ms ON, 96 ms OFF)
Cyclic signal of 1 second.
(504 ms ON, 496 ms OFF)
CAUTION
In the beginning, every signal is OFF.
The signals of R9091.0 and R9091.1 are always set at the
beginning of 1st level in every cycle.
Every pulse signal (ON–OFF) includes 8 ms errors.