2. SETTING FUNCTION
B–61863E/15
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
856
If you set ”RAM WRITE ENABLE” to ”YES”, it enables both the forcing
function and the override function.
NOTE
The override function also requires the setting of
”OVERRIDE ENABLE” in the setting parameters.
If you set ”DATA TBL CNTL SCREEN” to ”NO”, the data table control
screen does not be displayed.
If you set ”IO GROUP SELECTION ” to ”SHOW”, the setting screen for
the selectable I/O link assignment function is enabled.
PMC I/O screen is always displayed regardless of the running state of
programmer protection function.
However, Following function is executable according to state of each
setting parameter.
Protect functions individually Use all programmer protection functions
Operation
Related
setting
Enable
operation
Prohibit
operation
Related
setting
Enable
operation
Prohibit
operation
INPUTTING LADDER
K901.6/K18.6
K902.2/K19.2
Both
parameters
are 1
One of
them is 1
OUTPUTTING LADDER
(FDCAS,M–CARD)
K900.0/K17.0 Set to 0 Set to 1 K900.1
/K17.1
Set to 1 Set to 0
INPUTTING PMC
PARAMETER*1
K902.7/K19.7 Set to 0 Set to 1
(Caution 2)
OUTPUTTING PMC
PARAMETER*2
K902.6/K19.6 Set to 0 Set to 1
NOTE
1 Set NC to “Emergency Stop” state and set “PWE” of NC
setting screen to input PMC parameter.
2 Set EDIT mode to output PMC parameter.
2.6.7
RAM WRITE ENABLE
(PMC–SB7: K900.4,
PMC–SA1: K17.4)
2.6.8
DATA TBL CNTL
SCREEN (PMC–SB7:
K900.7, PMC–SA1:
K17.7)
2.6.9
IO GROUP SELECTION
(K906.1)
2.6.10
Protection of Each
Function of I/O Screen