B–61863E/15
L. MIGRATION OF LADDER PROGRAMS
BETWEEN DIFFERENT MODELS
APPENDIX
1533
(1)Differences between PMC–SA5/SB5/SB6 and PMC–SB7
The following list shows the difference of each PMC models. It is
possible to convert ladder for PMC–SA5, PMC–SB5, and PMC–SB6
into PMC–SB7. As for opposite compatibility, there are some
restrictions such as the range of PMC address. The ladder for
PMC–SB7 therefore cannot be converted into other PMC models.
16i/18i/21i–A 16i/18i/21i–B
Series
SA5 SB5 SB6 SB7
PMC
address
PMC/CNC
interface(F,G)
F0 to F255
G0 to G255
F0 – F511
G0 – G511
F0 – F767
G0 – G767
PMC/Machine
interface(X,Y)
X0 to X127
Y0 to Y127
X200 – X327
Y200 – Y327
Compatible
Keep relay(K)
for system software
K17 to K19 K900 to K909 K900 to K919
Basic instruction Compatible
Functional
instruction
END3
CTRB
MOVD
Not available Available
DISP Available Not available
NOTE
This list does not contain the addition of reserved area of
PMC address.
(2)The conversion of ladder from PMC–SA5/SB5/SB6 into PMC–SB7
(source program)
When you want to change ladder from PMC– SA5/SB5/SB6 to
PMC–SB7, you can convert the source program using FANUC
LADDER–III. Please refer to following manual for details.
FANUC LADDER–III OPERATOR’S MANUAL B–66234EN
”10.3 CONVERTING SEQUENCE PROGRAM BETWEEN
PMC MODELS”
The sequence of the conversion is as follows.
i) Convert a source program into the mnemonic file by FANUC
LADDER–III.
ii) Change the system parameters in the mnemonic file for
PMC–SB7 by text editor.
iii) Create a new source program for PMC–SB7 by FANUC
LADDER–III.
L.3
MIGRATION FROM
THE PMC–SA5/
SB5/SB6 TO THE
PMC–SB7
L.3.1
Compatibility of PMCs
for Series
16i/18i/21i–MODEL A
and B