L. MIGRATION OF LADDER PROGRAMS
BETWEEN DIFFERENT MODELS
B–61863E/15
APPENDIX
1548
The converter file is stored in ”OAppendix” of the installed
directory of FANUC LADDER.
FS0M–CNV.SYM: For converting to Series 0i–MA from
Series 0M
FS0T–CNV.SYM: For converting to Series 0i–TA from
Series 0T
(6)Replace the ladder data of the mnemonic form file(PMC–SA1) of (3)
with the ladder data of the mnemonic form file(PMC–M) of (1). (*D)
(7)Exit the text editor, and start up FANUC LADDER.
(8)Specify the PMC–RA1(SA1) as PMC model, and convert to the
source program from the mnemonic form file of (5).
(9)Delete all symbols and comment on the ”EDIT” screen.
*A Original mnemonic file
(PMC–M)
Converter file
FS0M–CNV.SYM
*B Converted mnemonic file
(PMC–SA1)
*C insertion
*D insertion
%@A
%@0
2 BINARY
3 NO
4 PMC–RA1
%
%@1
%
%@2
%
%@3
%
%@4
%
%@5
%
%@E
%@A
%@0
1 400
2 0
3 0
4 0
5 0
6 0
7 100
8 0
9 0
%
%@1
%
%@2
%
%@3
RD X21.4
WRT G121.3
RD.NOT X22.3
WRT.NOT G122.3
SUB1
SUB2
%
%@4
%
%@E
%@2
G000.0 G100.0
G000.1 G100.1
G000.2 G100.2
G000.3 G100.3
...
F132.5 F272.5
F132.6 F272.6
F132.7 F272.7
%
In case of FANUC LADDER–II (Example: Converting the ladder to
PMC–SA3 for Series 0i–TA from PMC–M for Series 0T)
(1)Prepare the mnemonic form file of PMC–M that you want to convert.
(**A)
(2)Input the new source program name on the ”Program Selection” in
FANUC LADDER–II, and select the ”PMC–SA3/RA3”, and select
the ”Off–Line function”.