iii) Search by instruction (Search by symbol)
Key in “L@@@@@
R ACT NL”.
Instruction to be searched
(ACT: Symbol name)
Line number with which the search is to be started
CAUTION
This search applies to such a case as the address of the
instruction to be searched is defined by a symbol and the
symbol is displayed.
iv) Search by the bit address or its symbol name
The specified address (only bit address) or its symbol name is
searched from the specified line number independently of a
command.
Type in ’L@@@@
????? NL’.
Bit address or its symbol name
Search start line number
Example) ’L1 R1.0 NL’
— Start searching bit address ”R1.0” from 1st line.
’L7 SMB NL’
— Start searching symbol name ”SM BL” defined at
bit address from 7th line.
v) Continuous search
A specified command, address (only bit address) or its symbol name
is searched from 2nd line displayed on the screen.
Type in ’L ?????
NL’.
Command, bit address or its symbol name
to be searched
Type in ’F NL’.
FIND: Search the same command, bit address or its
symbol name as that searched just before,
from 2nd line displayed on the screen.
Example) ’L R R0.1 <NL>’
— Search the command ”RD R0.1” from 2nd line
displayed on the screen.
’L R0.1 <NL>’
— Search the bit address ”R0.1” from 2nd line displayed
on the screen.
’L SYMBOL <NL>’
— Search the symbol name ”SYMBOL” defined at bit
address from 2nd line displayed on the screen.