B–61863E/15
5. FUNCTIONAL INSTRUCTIONSPMC SEQUENCE PROGRAM
151
Table 5 (a) Types and Processing of Functional Instructions (7) Part 2
Model
Name
SUB
number
Processing Series 21i MODEL A
number
PMC–SA1 PMC–SA5
ADDB 36 Binary addition f f
SUB 20 BCD subtraction f f
SUBB 37 Binary subtraction f f
MUL 21 BCD multiplication f f
MULB 38 Binary multiplication f f
DIV 22 BCD division f f
DIVB 39 Binary division f f
NUME 23 Definition of constant f f
NUMEB 40 Definition of binary constant f f
DISP 49 Message display
DISPB 41 Extended message display f f
EXIN 42 External data input f f
AXCTL 53 PMC axis control f f
WINDR 51 Window data read f f
WINDW 52 Window data write f f
FNC9X 9X Arbitrary functional instruction
MMC3R 88 MMC3 window data read
MMC3W 89 MMC3 window data write
MMCWR 98 MMC2 window data read f f
MMCWW 99 MMC2 window data write f f
DIFU 57 Rising edge detection f
DIFD 58 Falling edge detection f
EOR 59 Exclusive OR f
AND 60 Logical product f
OR 61 Logical add f
NOT 62 Logical negation f
END 64 End of subprograms f
CALL 65 Conditional subprogram call f
CALLU 66 Unconditional subprogram call f
SP 71 Subprogram f
SPE 72 End of a subprogram f
NOP 70 No operation f f
: Cannot be used f : Can be used